| Physical and Mechanical Properties
|
4
color-coded, unshielded twisted pairs cabled together and overall
taped-wrapped with a polyester tape, shielded with an aluminum foil
plus a tin-coated copper braid and overall jacketed.
Both cable ends terminated with fully shielded modular plug
connectors conforming to IEC 60603-7-3. |
| Basic
Cable Conductor : |
Stranded,
26 AWG, 7x0.16 mm, bare annealed copper |
| Wire
Insulation : |
Polyolefin
|
| Number
of insulated conductors : |
8,
twisted in 4 pairs. |
| Color
Code of Pairs : |
Blue
x White/Blue, Orange x White/Orange, Green x
White/Green, Brown
x White/Brown. |
| Overall
Tape Wrap : |
Polyester
tape, providing 100% coverage. |
| Overall
inner shield : |
Polyester-aluminum
foil (foil face out), providing 100% coverage. |
| Overall
outer shield : |
Tinned-copper
braid, providing 65% coverage, laid over the aluminum
foil. |
| Outer
Jacket and boots: |
LS0H
Halogen free flame retardant or PVC compound. |
| Standard
Jacket and boot Color : |
Light
Gray RAL 7032. Other colors available upon request. |
| Standard
Surface Marking : |
Includes
HCS P/N, cable description, Meter mark and Batch Number. |
| Cable
to plug tensile strength: |
9
Kgf (90N) min. |
| Pulling force : |
1
Kgf (10N) max. |
| Storage Temperature : |
-20
to +80C |
| Durability
: |
750
mating cycles |
| Cable
OD: |
5.7
mm nom. |
| Bend
radius: |
23
mm min. |
| Plug
housing material: |
Polycarbonate. |
| Plug
contact material: |
50
micro-inches gold plating over 100 micro-inches nickel
plated copper alloy. |
| Temperature operating range : |
-20
to +60C |
| Flame
Test : |
UL
1581 VW-1 and IEC 332-1. |
| Halogen
content in LS0H cables |
Null. |